10.2.2 Removing doors with pins
Open the door completely and insert the pins (supplied) into the holes from the
inside. Close the door to an angle of about 45° and lift it off. To reassemble, fit the
hinges into their grooves, then lower the door into place and extract the pins.
10.3 Removing the door seal
To permit thorough cleaning of the oven, the seal may be
removed.
10.4 Removing the internal glass panels
The glass in the door should always be kept thoroughly clean. For easier cleaning,
it is possible to remove the door (see “10.2 Removing the door”) and place it on a
canvas; or open it and block the hinges in order to extract the glass panes.
The glass panes of the door can be completely removed by following the
instructions provided below.
Warning: before removing the glass panes, make sure that at least one of the
door's hinges has been locked in the open position as described in points “10.2
Removing the door”. This operation might have to be repeated during the glass
removal process if the door is accidentally freed.
Warning: replace the glass panes in the same order and in the same direction in
which they were removed. Finally, if the door was not removed, unlock the hinges
and close it.
Warning: do not use the product without the glass inserted, otherwise the external
surface of the door will overheat.