Instructions for the Installer
40
15.2 Burner and nozzle characteristics table
Burner
Rated heating
capacity
(kW)
LPG – G30/G31 28/37 mbar
Nozzle
diameter
1/100 mm
By-pass
1/100
mm
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliaire 1.0 50 30 400 73 71
Semi rapid 1.8 65 33 500 127 125
Triple crown 4.0 100 65 1600 290 286
Burner
Rated heating
capacity
(kW)
NATURAL GAS – G20 20 mbar
Nozzle diameter
1/100 mm
Auxiliaire 1.0 72 (X) 400
Semi rapid 1.8 97 (Z) 500
Triple crown 4.0 135 (K) 1600
15.3 Arrangement of the burners on the hob
BURNERS
1. Auxiliary
2. Semi rapid
4. Triple crown
ø min e max (in cm.)
12 - 14
16 - 24
18 - 26