Smeg C9GGSSA Range User Manual


 
Instructions for the installer
10
4. ADAPTATION TO DIFFERENT TYPES OF GAS
Before carrying out the following operations, disconnect the appliance from the electricity supply.
The appliance is preset for natural gas G20 (2H) at a pressure of 20 mbar. In the case of operation with
other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas
taps. To change the nozzles, proceed as described in the following paragraphs.
4.1 Replacement of the cooking hob nozzles
1 Extract the pan stands and remove all the caps and flame-spreader crowns;
2 Unscrew the burner nozzles with a 7 mm socket wrench;
3 Replace the burner nozzles according to the type of gas to be used (see paragraphs “4.2 Burner and
nozzle characteristics table (60 cm model)” and “4.3 Burner and nozzle characteristics table (90 cm
model)”).
4 Replace the burners in the correct position.
The nozzles for using town gas (G110 – 8 mbar) are available from authorised service centres.