Smeg CIR34XS Cooktop User Manual


 
Instructions for the installer
14
5.2 Removing the hob (models with built-in control panel)
1. Remove the knobs, the griddles, the burner caps, the flame caps
and the two rear plugs;
2. Remove the screws “A” which fix the burner supports;
3. Raise the hob, sliding it off the ignition plugs and/or the
thermocouples and the gas tap rods;
5.3 Adjustment for ULPG
Check that the connection has been made as described in the “Gas
connection” section.
Undo the screw “D” and push the air regulator “C” fully down. Use a
spanner to remove the nozzles “B” and fit those of suitable type
following the instructions given in the tables for bottled gas ULPG 2.75
kPa. The nozzle must not be tightened to a torque of over 3 Nm.
ULPG – 2.75 kPa
Nominal gas Injector
Burner
Consumption (mm)
(MJ/h)
Auxiliary 4.8 0.60
Semi-rapid 5.9 0.65
Rapid 8.6 0.77
Rapid large 9.5 0.85
Fish pan 9.5 0.85
Wok 15.0 1.05