Instructions for the User
50
4.1.6 Electronic circuit board thermal protection
The appliance is equipped with a device which constantly measures the
temperature of the electronic circuit board.
If the temperature should exceed preset values, the device will trigger
specific functions to reduce the temperature and allow the ceramic hob to
keep operating correctly.
The following table lists the automatically triggered procedures and the
relative trigger temperature:
Operation
Trigger
temperature
Fan switches on at low speed 50 °C
Fan switches on at high speed 60 °C
Fan switches back to low speed 55 °C
Fan switches off 45 °C
Operating power is reduced from Power function to 9 76 °C
Operating power is reduced by one point for each
cooking zone
85 °C
All cooking zones switch off 90 °C
Cooking zones switch back on at reduced power 85 °C
All cooking zones return to normal operation 80 °C
The power displays on the hob flash to signal all operations of this kind.
4.1.7 Ceramic hob thermal protection
Each cooking zone is equipped with a device which constantly measures
its temperature.
If the temperature should exceed preset values, the device will trigger
specific functions to reduce the temperature and allow the ceramic hob to
keep operating correctly.
The following table lists the automatically triggered procedures and the
relative trigger temperature:
Operation
Trigger
temperature
Operating power is reduced from Power function to 9 250 °C
Operating power is reduced by one point 280 °C
Cooking zone switches off 300 °C
Power returns to set value 250 °C
The power displays on the hob flash to signal all operations of this kind.