Smeg CSE66-I Dishwasher User Manual


 
User instructions
46
6. Troubleshooting
The dishwasher is equipped with a self-diagnostics system that is capable of detecting and
signalling a number of possible faults.
TABLE OF FAULTS DETECTED BY THE SELF-DIAGNOSTICS SYSTEM
FAULT DESCRIPTION
E1
The anti-flooding system (where present) has been tripped.
E2 - E9
The water level limitation system has tripped.
E3
The appliance cannot heat the water.
E4
The temperature sensor is disconnected.
E5
The appliance cannot take in the water.
E6
The appliance cannot drain the water from the tank.
E7
The dishwasher cannot measure the precise water quantity that has been loaded.
E8
Problem on the water distribution system to the baskets.
The
E1
,
E2
,
E3
,
E4
,
E8
,
E9
alarms provoke the “forcing” to end cycle of the running program.
The
E5
,
E6
alarms interrupts the running program once the cause is resolved, it will bring bach
the execution of the program.
The alarm
E7
is visualized at the end of the cycle that comes, however, brought to the end
since the operation of the dishwasher is not harmed.
To “reset” an alarm is necessary:
Open and close the door, or turn off and on the machine. At this point is possible to program
the dishwasher again.
If the malfunction persists, contact your authorised Service Centre.
TECHNICAL DAT A
Width
597
÷
599 mm
Depth measured flush with the outer edge of
the control panel
Free standing: 600 mm
Fully integrated: 570 mm
Height
Free standing from 850 mm to 870 mm
Fully integrated from 820 mm to 870 mm
Capacity
12 Standard place settings
Water supply pressure
min. 50 – max. 900 KPa (min. 0.5 – max. 9 bar)
Electrical characteristics
See rating plate