Smeg CSE66-I2 Dishwasher User Manual


 
User instructions
35
ELECTRONIC SETTING
The value entered for this parameter establishes whether or not
regeneration
is to be carried out
at the end of the washing cycle, on the basis of the table below.
SETTING WATER HARDNESS REGENERATION
0 < 9°dH (15°dF) Not performed
1 < 15°dH (25°dF)
Performed every
5 cycles
2 < 23°dH (40°dF)
Performed every
4 cycles
3 < 34°dH (60°dF)
Performed every
3 cycles
4 < 46°dH (80°dF)
Performed every
2 cycles
5 < 58°dH (100°dF)
Performed
every cycle
Contact your local water board for information on the hardness of your water supply.
N.B.:
a
cycle
is a washing program.
Programming procedure:
Press the
PROGRAM SELECTION (2)
and
DELAYED START (3)
buttons simultaneously for
3 seconds until the
DISPLAY (7)
shows the symbol “
H
”;
Press the
DELAYED START
button
(3)
to modify the parameter;
Press the
PROGRAM SELECTION
button
(2)
to exit from the procedure.
SWITCH SETTING
According to the machine model, the selector which acts on the adjustment may be located:
inside the plastic locking ring located on the
right-hand
side, inside the dishwasher;
inside the water softener, just below the cap.
Both allow for adjustment to
5
settings: