Smeg FU65-5 Oven User Manual


 
Instructions for the Installer
9
US INSTALLATION ONLY – 3 – WIRE BRANCH CIRCUIT
Refer to picture 1, where local codes allow the
connection of ground wire from the applliance to
the branch circuit neutral wire (white colored wire):
- The ground wire must be attached first;
- If local codes permit, connect the green or
yellow-green ground wire from the appliance
and the white wire from the appliance to the
branch circuit neutral wire (white colored wire).
- Connect the red and black leads from the oven
to the junction using a UL/CSA listed wire
connectors to the corresponding leads in the
junction box.
pic.1)
US INSTALLATION AND CANADIAN INSTALLATION – 4 – WIRE BRANCH CIRCUIT
Refer to picture 2,
- Disconnect the green or yellow green from the
white lead;
- The ground wire must be attached first;
- Connect the green or yellow-green ground wire
from the appliance to the ground in the junction
box (green colored wire) using a UL/CSA listed
wire connectors. Do not connect grounding
wire to neutral wire in junction box.
- Connect the red and black leads from the
appliance to the corresponding leads in the
junctionbox using a UL/CSA listed wire
connectors
- Connect the white wire from the appliance to the
neutral (white colored wire) wire in the junction
box using a UL/CSA listed wire connectors.
pic.2)
Connect to a 20A fuse or circuit breaker. Connect to copper wire only or if connecting to
aluminium house wire use UL listed or CSA approved connectors, which are suitable for joining
aluminium with copper wires.
UL/CSA
listed wire
connector
UL/CSA
listed wire
connector