Smeg GCO90XG Range User Manual


 
Instructions for the installer
32
5.3 Regulation for natural gas
The hob has been inspected for G20 (2H) natural gas at a pressure of
20 mbar. To allow the unit to work with this type of gas, perform the same
operations described in paragraph “5.2 Regulation for LPG”, but choose
the nozzles and regulate the primary air for natural gas, as shown in the
following table and in paragraph "
5.4 Regulation of primary air”. After the
regulations have been carried out, restore the seals with sealing wax or
equivalent material.
Burner
Rated
heating
capacity
(kW)
Natural gas – G20 20 mbar
Nozzle diameter
1/100 mm
Reduced flowrate
(W)
Auxiliary (1) 1.05 73 380
Semi-rapid (2) 1.65 92 380
Rapid (3) 3.1 126 750
Ultra rapid (4) 3.3 130 1200
internal (5) 1.05 73 380 Double crown
external (5) 3.9 140 1200
Fish pan (6) 2.9 123 800
5.4 Regulation for town gas
To allow the unit to work with this type of gas, perform the same
operations described in paragraph “5.2 Regulation for LPG”, but choose
the nozzles and regulate the primary air for town gas, as shown in the
following table and in paragraph “5.5 Regulation of primary air”.
Attention! Only units with safety valves can be used with town gas
G110.
Bruciatore
Portata
termica
nominale
(kW)
Gas città – G110 8 mbar
Diametro ugello
1/100 mm
Portata ridotta
(W)
Ausiliario (1) 1.05 132 380
Semirapido (2) 1.65 165 380
Rapido (3) 3.1 240 800
Ultra rapido (4) 3.3 250 1200
interna (5) 1.05 132 380 Doppia corona
esterna (5) 3.9 290 1200
Pescera (6) 2.9 230 800
I valori relativi al gas città si riferiscono agli apparecchi della categoria III 1a2H3+.