User instructions
38
CODE PHASES LIGHTS DESCRIPTION
E7
The appliance is not able to measure the amount
of water loaded accurately (on models with turbine
flow-regulator only).
E8
Anomaly in the system which distributes water to
the basket (where installed).
E9
The maximum level of water for loading has been
exceeded (on models with turbine flow-regulator
only).
• The E1, E2, E3, E4, E8, E9 alarms provoke the “forcing” to end
cycle of the running program.
• The E5, E6 alarms interrupts the running program once the cause is
resolved, it will bring bach the execution of the program.
• The alarm E7 is visualized at the end of the cycle that comes,
however, brought to the end since the operation of the dishwasher is
not harmed.
To “reset” an alarm is necessary:
• Open and close the door, or turn off and on the machine. At this
point is possible to program the dishwasher again.
If the fault persists, call the authorised Technical Service Centre.
TECHNICAL DATA
Width
597 ÷ 599 mm
Depth measured flush with the
outer edge of the control panel
Free standing: 600 mm
Semi-integrated: 570 mm
Height (depending on models)
Free standing: from 850 mm to 870 mm
from 890 mm to 910 mm
Semi-integrated: from 820 mm to 870 mm
from 860 mm to 910 mm
Capacity
14 Standard place settings
Water supply pressure
min. 0,05 - max. 0,9 MPa (min. 0.5 – max. 9 bar)
Electrical characteristics
See rating plate