Smeg PGF75F Cooktop User Manual


 
Instructions for the installer
30
3.2 Burner and nozzle characteristics table
Burner
Rated
heating
capacity
(kW)
LPG – G30/G31 30/37 mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
flow rate
(W)
Flow rate
g/h G30
Flow rate
g/h G31
Auxiliary (1) 1.05 50 30 * 28 ** 350 76 75
Semi rapid (2) 1.75 65 33 * 32 ** 450 130 128
Ultra Rapid (3) 3.4 94 65 * 63 ** 1500 247 243
*/**: diameters marked * and ** must be fitted respectively on valves marked * and
**shown in point "4.1 Adjusting the minimum setting for natural gas".
Burner
Rated
heating
capacity
(kW)
Natural gas – G20 20 mbar
Nozzle diameter
1/100 mm
Reduced flow rate
(W)
Auxiliary (1) 1.05 72 350
Semi rapid (2) 1.75 97 450
Ultra Rapid (3) 3.5 133 1500
3.3 Arrangement of burners on cooking hob
BURNERS
1. Auxiliary
2. Semi rapid
3. Ultra rapid