38
Instructions for the installer
10. ADAPTATION TO DIFFERENT TYPES OF GAS
Before carrying out the following operations, disconnect the appliance
from the electricity supply.
The appliance is tested for natural gas G20 (2H) at a pressure of 20
mbar. In the case of operation with other types of gas the burner nozzles
must be changed and the minimum flame adjusted on the gas taps. To
change the nozzles, proceed as described below.
10.1 Replacement of nozzles on the cooker hob
1 Extract the grids and remove all the caps and flame-spreader crowns;
2 Unscrew the burner nozzles with a 7 mm socket wrench;
3 Replace the burner nozzles according to the type of gas to be used
(see point "10.2 Burner and nozzle characteristics table").
4 Replace the burners in the correct position.
The nozzles for using town gas (G110 – 8 mbar) are available from
authorised service centres.