Smeg SA62MFX5 Cooktop User Manual


 
Instructions for the installer
21
Overall dimensions: location of gas and electrical connection points (all measures in mm).
A 60
B 410
C 100
D 140
14.2 Gas connection
This appliance is suitable for installation with Natural Gas or ULPG (propane).
Refer to page 12 for the relevant burner pressure and appropriate injector
sizes. When the appliance is to be connected to Natural Gas then the pressure
regulator supplied must be fitted to the gas inlet. A test point (for checking the
gas pressure) is supplied either with the regulator or as a separate fitting in the
case of ULPG (propane) appliances.
Connection of the appliance to the gas supply must be in accordance with the
requirements of AS5601. A ½” BSP connector at the inlet is recommended and
the gas supply line to the appliance must be of adequate length to allow
sufficient withdrawal of appliance for service or disconnection and be
1. annealed copper pipe, or;
2. flexible hose according to AS/NZ1869 & be at least Class “B”, 10 mm
diameter.
The cooker must be installed with provision to allow the gas to be turned off
and disconnected for servicing and removal of the appliance as required from
the gas supply.
Before the cooker is operated make certain all relevant parts are placed in the correct position.
When the installation is completed the installation connections of cooker will require to be leak tested,
the burner operating pressure and flame checked and adjusted.
Warranty service calls do not cover these adjustments!
To check the operating pressure of the appliance it is recommended at least 2 large size burners are
used. Ensure appliance is secured to wall when installation is completed.
N.G. The regulator supplied must be fitted to the ½ BSP thread at the rear of the appliance. An
approved manual shut-off valve must be installed. The N.G. regulator must be checked and adjusted
to 1.0kPa after installation.
U.L.P.G. Can be connected to the inlet fitting directly. The pressure must be
checked to ensure it is operating at 2.75kPa. A separate test point fitting must
be installed between the piping & the appliance for the pressure to be checked
to ensure it is operating at 2.75kPa.