Smeg SE62CX Cooktop User Manual


 
224810 21
4.3 Electrical connection
(Connected loads and model designation: see front of the operating instructions)
This appliance may only be connected to the electricity supply by an approved electrician who must ensure that
the installation complies with the statutory regulations (Germany VDE, Austria ÖVE, Switzerland SEV, etc.). The
electrician must ensure that these regulations and those laid down by the local electricity supply company are
observed.
In addition, make certain to observe the assembly instructions of the electrical appliance (e.g. built-under oven,
built-in oven or built-in switchbox) with which this cooking surface is combined.
When connecting the electrical appliance, install an all-pole disconnecting device with a contact gap of at least
3 mm.
Make the plug connection between the cooking zones and switches.
The protective conductor (green/yellow strand) is attached to the protective conductor pins of the switching
element.
Insert the plug connections of the oven hob (of the respective cooking zone) into the plug connection sockets
provided on the oven and/or switchbox. Make certain to observe the terminal connection diagram.
4.4 Service work
Always disconnect the appliance from the mains before carrying out repairs, this means the cut-out device must
be opened. If you have to contact our service department, always quote the type and make numbers. You can find
these numbers on the rating label or on page 1 of the Operating Instructions.
Each time the glass ceramic hob is removed from the worktop, check the seals and replace if necessary.