Southbend EZ-5 Electric Steamer User Manual


 
SPECIFICATIONS MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS
PAGE 4OPERATORS MANUAL 1178387 REV 2
SPECIFICATIONS
SPECIFICATIONS
DIMENSIONS
A
B
C
D
E
FRONT VIEW
SIDE VIEW
TOP VIEW
= Electrical Connection Terminal Block
Width Height Depth Electrical Connection Crate Size
Model
A B C D E Width Depth Height Volume
Crated
Weight
EZ-3
16.375"
416 mm
24.25"
616 mm
30.25"
768 mm
6"
153 mm
2.44"
62 mm
20"
508 mm
34"
864 mm
37"
940 mm
14.6 cu. ft.
0.41 cu. m.
150 lbs.
68 kg.
EZ-5
16.375"
416 mm
30.25"
762 mm
30.25"
768 mm
6"
153 mm
2.44"
62 mm
20"
508 mm
34"
864 mm
37"
940 mm
14.6 cu. ft.
0.41 cu. m.
175 lbs.
79 kg.
Internal Dimensions: EZ-3: 13.5" W x 22" D x 9.5" H; EZ-5: 13.5" W x 22" D x 15.5" H
UTILITY INFORMATION
One electric connection is required.
IMPORTANT: UNIT MUST BE LEVEL FOR PROPER OPERATION. WARRANTY WILL BE VOIDED FOR
IMPROPER INSTALLATION.
All units shipped per customer order, three phase or single phase.
Kit available for field conversion to three phase or single phase.
Max. Amps per Line
EZ-3 EZ-5
Total Connected Amps
1 Phase 3 Phase 1 Phase 3 Phase
208 V 60 Hz 40 24 57 33
220 V 50/60 Hz 38 23 54 31
240 V 60 Hz 35 21 49 29
380/220 V 50 Hz 23 14 31 19
415/240 V 50 Hz 21 13 29 17
480 V 60 Hz 18 13 25 15
Circuit must be wired for maximum amps at required voltage.