Southbend SSB-45 Oven User Manual


 
OPERATION RADIANT STEAKHOUSE BROILER
PAGE 8 OF 20 OWNERS MANUAL 1190950 (02/09)
Figure 3
Broiler Controls and Components
Removable
Grease Chute
Pilot Adjustment
Access Hole
Removable
Heavy-Duty
Broil Rack
Removable
Stainless Steel
Drip Pan
Removable
Grease Drawer
V
ariable High-Low-Off
Independent Gas
Adjustment
Release Paddle
Nine-Position Rack
Adjustment Arm
Gas Regulator with
1" Rear Connection
Flue Vent Chambe
r
Keep the drip pans in place below the rack when broiling! Without them in place,
excessive air will be pulled past the burners, reducing temperature and cooking efficiency.
LIGHTING AFTER GAS HAS BEEN SHUT OFF
When turning on the main gas supply to an appliance or a group of appliances, do the following:
1. Make sure that all the control valves and power switches of all the appliances are in the OFF position.
2. Turn on the main gas supply valve.
3. Light the standing pilots of each connected appliance.
LIGHTING BROILER PILOTS
The pilots should burn continuously unless the broiler is to be completely shut down. The broiler cavity has two or
three pilots, one near each burner. If the pilots are extinguished, the pilot gas supply is NOT automatically interrupted.
To light the pilots, do the following:
1. Turn the control valves on the front of the broiler to OFF.
2. Turn on the gas supply to the broiler (if not already on).
3. Light the pilots.
SHUTDOWN OF BROILER
To place the broiler in a standby state (ready for use), turn the burner control valves to OFF. The pilots will remain lit.
To completely shut down the broiler for an extended period (or prior to disconnecting the gas supply), turn OFF the
manual shutoff valves of all gas supply connections. (This will extinguish all pilots.)