FAULT CODES
1 APECS unit not calibrated yes Have engine serviced by an Authorized Stanley Dealer.
2 Engine speed excessive yes Have engine serviced by an Authorized Stanley Dealer.
3 Engine speed unusually low yes Have engine serviced by an Authorized Stanley Dealer.
4 Engine shutdown due to engine
protection input
yes Have engine serviced by an Authorized Stanley Dealer.
5 Factory settings lost yes Have engine serviced by an Authorized Stanley Dealer.
6 External pot out-of-range no Have engine serviced by an Authorized Stanley Dealer.
7 Accelerator position / idle
switch conict
no Have engine serviced by an Authorized Stanley Dealer.
8 Controller unit failed yes Have engine serviced by an Authorized Stanley Dealer.
9 Limiting excessive
actuator current
no Have engine serviced by an Authorized Stanley Dealer.
10 Engine speed input
signal missing
no (Active only in Auto crank mode).
Check speed sensor wiring.
Check starter motor.
11 Auto crank unable to
start engine
no Check fuel.
12 Auxiliary output is shorted no Check the lamp or relay hooked to the output. If fault is
still present, have engine serviced by an authorized
Stanley Dealer.
13 Auxiliary output #2 is shorted no Check the lamp or relay hooked to the output. If fault is
still present, have engine serviced by an authorized
Stanley dealer.
14 Actuator disconnected or
open circuit
no Check actuator wiring and actuator resistance.
Resistance should be less than 10 ohms.
FLASH ENGINE
CODE FAULT SHUTDOWN CORRECTIVE ACTION