If symptoms of poor performance develop, the following chart can be used as a guide to correct the problem.
When diagnosing faults in operation of the intensier, always check that the hydraulic power source is supplying the
correct hydraulic ow and pressure to the intensier as listed in the table. Use a ow meter known to be accurate.
Check the ow with the hydraulic uid temperature at least 80 °F/27 °C.
PROBLEM CAUSE SOLUTION
No output. Couplers or hoses blocked. Remove obstruction.
Input pressure and return line
hoses reversed at ports.
Be sure hoses are connected to the
proper ports.
No oil in reservoir. Fill reservoir to proper level.
High-pressure relief valve stuck
open.
Test and adjust as specied in Service
section.
Motor to pump hose leaking. Remove and replace hose.
Intensier turned over with vent
assembly down.
Return intensier to upright position.
Oil mist from center of motor
housing assembly.
Rear drive shaft seal bad. Replace shaft seal located behind shaft
bushing in motor housing assembly.
Oil leaking from vent assembly. Oil reservoir over lled. Reduce oil level to the top of the high-
pressure pump as viewed through the
vent assembly port while the intensier
is in the horizontal position. (Reservoir
must have room for oil expansion.)
Defective shaft seal. Seal is located
in the oil seal plate between the
motor housing assembly and pump
housing.
Turn off intensier. Remove vent
assembly and turn on intensier.
Operate compression tool or cutter. If oil
reservoir lls up and overows, replace
the shaft seal.
TROUBLESHOOTING