Sterling 100 Blender User Manual


 
Continuous Loss-in-Weight Blenders Chapter 3: Installation 32
will suffice. The weight will be in pounds, unless the blender is provided for metric display
operation (kilograms).
Given the two weight points on the load cell scale, the controller will be able to determine any
other weight on the load cell span. This is limited to the maximum capacity of the load cell.
The standard load cell used on these blenders have a span accuracy of 1/10
th
%.
The maximum capacity of each load cell is clearly marked on the fixed top of the load cell.
This value will be indicated in kgs. (2.2 lbs. = 1 kg.)
Figure 11: Blender Calibration Weight
Scale Calibration
During the initial setup of the blenders, the feeder units will need to be setup. Most of these
items should have been setup at the factory before the unit shipped.
To calibrate the scales on each of the feeder units, follow the instructions below: