5.1. Main te nance in ter vals
Daily: check warn ing signs on equip ment for good
leg i bil ity and com plete ness.
Weekly: check the main te nance unit
check the op er at ing pres sure in the fac tory
ductwork sys tem (max. 6 bar (87.02 PSI) sys tem
overpressure)
Monthly: check the sealings on the fil ter car tridges
(ac cord ing to the ac cu mu la tion of dust)
Ev ery six months: check fil ter con tam i na tion, if nec es sary clean or
re place the fil ter car tridges
check all elec tri cal and me chan i cal con nec tions
for proper fit
check the set tings of the level probes (if avail able)
check the seal ing ring on the out let flap
Yearly: re place the seal ing ring on the out let flap
F
The given main te nance in ter vals are av er age val ues.
Check whether in your in di vid ual case the main te nance in -
ter vals must be short ened.