Stoelting 4231G Freezer User Manual


 
20
Low overrun 1. Mix inlet regulator (carburetor) missing. 1. Replace mix inlet regulator (carburetor).
2. Mix inlet regulator (carburetor) “O” Ring 2. Replace mix inlet regulator
missing. (carburetor) “O” Ring.
3. Mix inlet regulator (carburetor) air tube 3. Clean with sanitizer brush.
blocked.
Front door leaks. 1. Front door knobs are loose. 1. Tighten knobs.
2. Spigot parts are not lubricated. 2. See paragraph 3.11.
3. Chipped or worn spigot “O” Rings. 3. Replace “O” Rings.
4. “O” Rings or spigot installed wrong. 4. Remove spigot and check “O” Rings.
5. Spigot hole in front door nicked or 5. Replace front door.
scratched.
Hopper will not 1. EPR valve needs to be adjusted. 1. (See note 1.)
Maintain mix 2. Temperature control failure. 2. Replace. (See notes 1 or 2.)
temperature below 3. Refrigeration problem. 3. Check system. (See note 1.)
45°F (7°C).
1. Must be performed by a qualified service person.
2. The local dealer, distributor or Stoelting, LLC, Service Department should be contacted. Write or call:
Stoelting, LLC
502 Hwy. 67,
Kiel, WI 53042
Phone (920) 894-2293.