Planning Information
Built-In Model 650G
Dimensions in parentheses are in
millimeters unless otherwise specified.
5
INSTALLATION NOTES
R
efer to the illustrations and specifications
for overall dimensions, finished rough opening
dimensions and installation specifics.
A
llow the door to open a minimum of 90˚ or
you'll have problems removing drawers. With
the door opening at 90˚, you may have to move
drawers slightly to clear the door interior. Refer
to the minimum door swing clearance in the
specifications chart.
For corner installations, allow for a minimum
3" (76) filler so that the door can open to 90˚.
If you're using raised panels, consider using a
wider filler.
Be sure to add the filler strip width to your
finished rough opening dimension. In any side-
by-side installation without a filler strip, add an
additional
1
/2" (13) to your combined numbers.
This will allow for the proper width.
Refer to the full-scale illustrations at the end
of this section for specifics on door openings
and filler size alternatives.
If your client has chosen the stainless steel
design, the unit will be shipped complete with
wrapped stainless steel doors and handle
hardware. You will not have to install front
panels.
If your client has chosen the framed or
overlay design, you will be adding front panels
to give the unit the custom Sub-Zero look. The
overlay design also allows you to add your own
handles, or you may choose accessory handles
available through your Sub-Zero dealer. Refer to
pages 6–11 for detailed information on adding
panels.
The refrigerator door panel must include a
cut-out to accommodate the window. Refer to
the panel specifications for exact dimensions.
The glass portion of the door must be exposed
and not covered b
y any part of the panel.
F
or Built-In models with an automatic ice
maker, rough in the water supply line. Connect
a
1
/4" OD copper line to the house supply
, being
sure to use an easily accessible shut off valve
between the supply and the unit.
Do not use self-piercing valves. A saddle
valve kit (4200880) is available from your
Sub-Zero dealer. To obtain local dealer informa-
tion, visit the Locator section of our website,
subzer
o.com.
A
line filter is required when water condi-
tions have a high sediment content. The ice
maker operates on water pressure of 20 psi
(1.4 bar) to 100 psi (6.9 bar). In some cases a
r
everse osmosis water filter system may not be
able to maintain the minimum water pressure
consistently.
The water line should be routed up through
the floor within
1
/2" (13) from the back wall and
no higher than 3" (76) off the floor. If you have
to come through the wall, make sure the water
line is no more than 3" (76) from the floor.
Locate water supply within the shaded area
shown in the installation illustration.
Regardless of the routing, allow 3' (.9 m) of
excess copper tubing to remain outside the wall
or floor for easy connection to the unit.
A 115 volt, 60 Hz, 15 amp electrical supply
is required. The supply circuit for this appliance
must be protected by a 15 amp fuse or circuit
breaker. It is recommended that a separ
ate
circuit, serving only this appliance, be provided.
All Built-In models are equipped with a 6'
(1.8 m) power supply cord with a 3
-prong
grounding plug which must be plugged into a
mating 3
-prong grounding type wall receptacle.
Locate electrical within the shaded area shown
in the installation illustration.
You must follow all National Electrical Code
regulations. In addition, be aware of local codes
and ordinances when installing your service.
To prevent the unit from tipping forward and
provide a stable installation, the unit must be
secured in place with an anti-tip blocking kit. If
there is a solid soffit a
bove the unit with clear
-
ance between the unit and the soffit of 1" (25)
or less, you won't need to block the unit.
For installations with clearances of more
than 1" (25),
you must block the unit with the
anti-tip bloc
king kit (wood bloc
k and hardw
are)
provided with each Built-In unit.
Refer to the
Built-In Installation Instructions
packed with the appliance, which provides
step-b
y-step pr
ocedures for making sure the
unit is installed properly.