Troubleshooting
ICE PRODUCTION
No ice.
Verify
indicator appears in control panel display.
Verify ice maker has been on for at least 24 hours.
Verify freezer temperature near 0°F.
Verify ice container is properly installed.
Verify ice maker arm in down position.
Verify water is being supplied to unit.
Verify water lter has been replaced within the last 12
months and installed properly.
Verify water lter has been removed if a reverse osmosis
ltration system is being utilized.
Verify
indicator is not ashing. If ashing, touch MAX
ICE and ICE MAKER on the control panel simultaneously.
Blue or green ice.
Possible copper supply line corrosion. Contact plumber
to clean or replace.
Black ecks in cubes.
Stop use and contact Sub-Zero factory certied service.
Bad taste.
Defrost freezer and clean with soap and water.
Place coffee grounds or charcoal briquettes in freezer to
absorb odor.
Hollow cubes.
Clean condenser. Contact Sub-Zero factory certied
service if unresolved.
TROUBLESHOOTING
ODOR
Unit should be cleaned before using for the rst time.
This will clear any odors that may have been trapped
during shipping.
Replace air purication cartridge.
Clean unit and shelving thoroughly.
Uncovered food could create odor which may require
cleaning.
Remove and clean drain pan located behind kickplate,
and reinstall.