9
WOLF COOKTOP VENTILATION HOOD USE & CARE
HEAT SENTRY FEATURE
The heat sentry feature will help you maintain
your cooking environment and allows your
v
entilation hood to sense when blower opera-
tion is needed.
The heat sentry feature is always in wait and
is activated when the exhaust temperature
f
rom the hood reaches 206˚F (97˚C). At this
temperature, the blower motor speed will
automatically adjust to the next highest speed.
For example, if the blower motor is in low
speed and the threshold temperature is
reached, the blower will increase to medium
speed. The corresponding LED on the control
will blink to indicate the heat sentry feature
blower speed.
Once heat sentry feature is activated, the
ventilation hood will continue to monitor
exhaust temperatures every three minutes. If
the exhaust temperature reaches 206˚F (97˚C),
the blower speed will increase to the next
highest speed and the corresponding LED
will blink. If after three minutes the exhaust
temperature falls below 174˚F (79˚C), the
blower speed will decrease to the next lowest
speed.
If the blower was off prior to heat sentry
feature activation, the unit will turn off when
e
xiting the heat sentry feature.
W
hen the blower speed returns to the original
setting prior to heat sentry feature activation,
the corresponding LED will stop blinking and
r
emain constant. The unit has exited the heat
sentry feature.