E SERIES SINGLE OVENS
Required power supply:
220-240V AC, 50/60 Hz
Maximum connected load:
5.1 kW
Total amps:
21 amps
Minimum supply wire size:
L1, N and
ground–10 AWG
E SERIES DOUBLE OVENS
Required power supply:
220-240V AC, 50/60 Hz
Maximum connected load:
8.9 kW
Refer to the wiring diagram showing the
connections for each lead to the terminal box
on the unit.
ELECTRICAL REQUIREMENTS
The complete appliance must be properly
grounded at all times when electrical
power is applied.
NOTE: Improper connection can result in
a fire hazard.
GROUND
L1
N
Wiring diagram
Verify that power is disconnected from
the electrical box before proceeding.
Open the terminal box to expose the screws
with corresponding numbers. Loosen the 1, 5,
and ground screws. Run the cord through the
strain relief hole and into the terminal box.
Attach the Neutral wire to the number 1
position. Line should be attached to the 5
position and attach the ground to the corre-
sponding ground screw. After tightening the
screws, tighten down the cord strain relief and
close the cover to the terminal box without
pinching any of the wires.