14
I
N STA LL AT IO N
D
O O R PA N E L I N S TA L L AT I O N
You should be sure of the door panel size and
placement before proceeding with the installa-
tion. If you have questions, contact your
Sub-Zero dealer or cabinet supplier. Instruc-
tions regarding sizing of the door panel are
provided in the Sub-Zero design guide.
For door handle hardware, a D-style pull
centered on the edge opposite the door hinge
side is recommended. Screw heads may have
to be countersunk to ensure that the hardware
does not interfere with the panel fitting flush
with the unit door.
R
emove the handle side bracket attached to
the front of the door and set aside.
Place the door panel lying face down on a
protected surface to ensure the front is not
scratched or damaged.
Position the template provided flush with the
upper edge of the door. Be sure you are
following the exact location for the RH or LH
door position. Refer to the illustration below.
IMPORTANT NOTE:
Remember you are
viewing the door panel from the back side in
the illustration. The overall size of the panel
shown is the minimum size necessary to cover
the door of the unit. The exact measurements
of your door panel may vary depending on the
particular installation you are following.
Once you have located the proper position for
the hardware, mark the holes, remove
template, and drill pilot holes for mounting of
the hardware. We recommend starting the first
few holes, positioning the hardware, drilling
remaining pilot holes, and securing the
mounting brackets with the #8 x
1
/2" screws.
Refer to the illustrations below.
Flush with Top and Side
of Panel
Template position
Right-hand door panel
Left-hand door panel
P
A N E L
D E S I G N
Additional panel
design information
can be found in
the Sub-Zero
design guide.
Check our website
at subzero.com.
D O O R PA N E L D I M E N S I O N S
Door Panel Width –
1
/8" (3) reveal 15" (381)
Door Panel Height –
1
/8" (3) reveal
4" (102) toe space 30
3
/8" (772)
Door Panel Thickness
5
/8" (16) min
Door Panel Weight 15 lbs (6.8 kg) max
Dimensions may vary
+_
1
/8" (3).
S U B - Z E R O I CE M ACH IN E I N S TA L L AT I O N