(see figure 12)
4 - Fit bowl gasket around its seat.
Note: the largest brim of gasket must face against the rear
wall (see figure 14).
figure 14
5 - Carefully insert the auger into the evaporator use caution
to prevent it from hitting the rear wall (see figure 15).
figure 15
6 - Install the outer spiral. Slide it over the evaporator until its
front notch engages with the exposed end of the auger
shaft (see figure 16).
figure 16
7 - Push the bowl toward the rear wall of the unit until it fits
snugly around the gasket and its front fastening hooks are
properly engaged (see figure 17).
figure 17
8 - On 369 MODEL install the lateral tray by reversing the
disassembly steps (see figure 6).
9 - Use fresh product to chase any remaining sanitizer from
the bottom of the bowl(s). Drain this solution. Do not rinse
out the machine.
5. 4 IN-PLACE SANITIZATION
The In-Place Sanitization prior to starting the machine may be
performed prior to starting the machine, if needed, this should
only be performed, in addition to the Disassembled Parts
Sanitization, but never in lieu of it.
1 - Prepare two gallons of a warm (45-60°C / 120-140 °F)
sanitizing solution (100 PPM available chlorine
concentration or 1 spoon of sodium hypoclorite diluted with
half a gallon of water) according to your local Health
Codes and manufacturer’s specifications.
2 - Pour the solution into the bowl(s).
3 - Using a brush suitable for the purpose, wipe the solution
on all surfaces protruding above the solution-level and on
the underside of the top cover(s).
4 - Install the top cover(s) and operate the unit. Allow the
solution to agitate for about two minutes. Drain the solution
out of the bowl(s).
5 - Use fresh product to chase any remaining sanitizer from
the bottom of the bowl(s). Drain this solution. Do not rinse
out the machine.
6 ROUTINE MAINTENANCE
1 - Daily: inspect the machine for signs of product leaks past
seals and gaskets. If proper assembly does not stop leaks
around seals or gaskets, check for improper lubrication,
worn or damaged parts. Replace parts as needed.
2 - Monthly on 369, 370 and 371 models: remove the dust
ATTENTION
A damaged power cord must be replaced by an
authorized service agent. Failure to comply main result