25
Models 8752 & 8756 with Horizon® Pump Operating Procedures
Step 13
Insert the parts assembled in Step 12 into the valve
outlet fitting.
Figure 37
Step 14
Slide the pressure relief valve onto t he main pump
assembly.
Figure 38
Step 15
Secure the pressure relief assembly by installing the
retaining pin into the r ear retaining pin plate.
Figure 39
Note: The assembled parts must a lign with t he
matching hole in the mounting plate.
Step 16
Attach one end of the flare line to the pressure relief
valve outlet fitting of the Horizon® pump. Attach the
other end to the mix feed tube.
Figure 40