Thermador DWHD651GFP Dishwasher User Manual


 
285
1.800.735.4328 | THERMADOR.COM
DISHWASHERS
DISHWASHERS SAPPHIRE6-PROGRAM
Models: DWHD650GFP, DWHD650GPR
INSTALLATION OPTIONS
CUSTOM DOOR PANELS (DWHD650GPR)
Fully integrated models allow you to have
a custom door panel made to match your
cabinetry. The custom door can be a two-piece
configuration to look like a drawer at the top
and a cabinet door at the bottom or like a
single full-length door. A template is included
with the fully integrated models to explain the
mounting procedure.
NOTE: The door springs that are included with
the fully integrated units will provide proper
function for custom door panels weighing
between 9 and 18 pounds. No tension
adjustment screws are necessary.
DWHD650GFP
DWHD650GPR
DISHWASHER & CUTOUT DIMENSIONS
WATER AND ELECTRICAL LOCATION DIMENSIONS
WATER AND ELECTRICAL
LOCATIONS
For proper dishwasher operation and
appearance, ensure that the enclosure is square
and has the dimensions shown. Plumbing and
electrical service must enter shaded area.
Make required openings to allow for passage
of the water, drain and electrical line. In order
to avoid interference with the dishwasher when
sliding it into the cabinet, place your openings
within the dimensions shown.
Sapphire Series Required Openings:
4
1
/4" x 2" (108 x 52 mm) - To pass the
included electrical supply junction box
through to an adjacent cabinet
4" x 2" (100 x 50 mm) - To pass the included
water supply line toward the water supply
1
1
/4" (32 mm) diameter - To pass the
dishwasher drain hose toward the drain
connection
NOTE: If the incoming electric supply, water
supply and drain connections are all in the
same cabinet, the one 4
1
/2" x 2
1
/2" hole will
be large enough for all three to pass through.
The dishwasher electrical supply junction box
and dedicated receptacle must be mounted
in an accessible cabinet adjacent to the
dishwasher (do not mount the junction box
or receptacle behind the dishwasher). You
will need a 4
1
/4" x 2" (108 x 51 mm) opening
through the cabinet in order to pass the
junction box through.
The electrical supply can be connected in one
of two ways:
– Use the included three prong plug and
junction box to connect to a dedicated
household receptacle.
– Permanently connect to household or
field wiring
90°
24" (61cm)
2" (5cm)
34¼"(86.7cm)
4" (10cm)
24"-24
¼"
(61-61.6 cm)
Describes
the space
(if any)
between
cabinets
and wall
Describes
the cutout
of adjoining
cabinets