Thermador HDDW 36DS Ventilation Hood User Manual


 
PAGE 9
REPLACING THE BULBS
1. Switch off the extractor hood and pull out the mains
plug or switch off the electricity supply at the fuse box.
When switched on, the halogen bulbs become very
hot. Even for some time after the bulbs have been
switched off there is still a risk of burns.
2. Remove the bulb ring with a screwdriver or similar tool.
3. Replace the halogen light bulb (conventional halogen
bulb, 12 Volt, max. 20 Watt, G4 bulbholder).
Caution: Plug-in bulbholder.
Take hold of the bulb with a clean cloth.
4. Re-insert the bulb ring.
5. Restore the power by inserting the mains plug or
switching on the fuse.
Note: If the light does not function, check that the bulbs
have been inserted correctly.