Thermador SGN30 Cooktop User Manual


 
Page 7
STEP SIX: POWER SUPPLY HOOKUP
Rough-In Box
1/2" Female
Pipe Threads
Supply Cord
120 V
Of Wall
Receptacle
Gas Shut-Off Valve
Gas Stubout
Cabinet Floor
Flex Gas Line
Pressure
Regulator
Shows
Direction of
Gas Flow
2"
11-5/8" for GGS30, GGN30,
SGS30 & SGN30
14-7/8" for GGS36/365,
GGN36/365, SGS36G &
SGN36G
Opening for Gas
Connection &
Electrical Cord
Table 1
120 15 Ampere 60 Natural 5 Inch Water Column
Propane 10 Inch Water Column
Fig. 8
Fig. 9
MODEL VOLTS CIRCUIT REQUIRED HZ. GAS MANIFOLD PRESSURE
GGS30, GGN30
GGS36, GGN36
GGS365, GGN365
SGS30, SGN30
SGS36G, SGN36G
!
Important Electrical
Connection Instructions
This appliance is now ready for con-
nection to the properly grounded and
polarized three-prong wall receptacle
located within reach of 6-foot supply
cord. The circuit required is 15 Amp,
120Volt, 60 Hz. Before connecting
supply cord to wall receptacle make
certain that wall shut-off valve and
all burner controls are in “OFF” posi-
tion.
Operation of electric igniters should
be checked after unit and gas supply
have been carefully checked for leaks
and unit is connected to electric
power.
L of Cutout
C
C
L
Important Notes for Gas
Units:
(a) The appliance and its indi-
vidual shutoff valve must be
disconnected from the gas sup-
ply piping system during any
pressure testing of that sys-
tem at test pressures in excess
of 1/2 psig (3.5 kPa).
(b) The appliance must be isolated
from the gas supply piping sys-
tem by closing its individual
manual shutoff valve during
any pressure testing of the gas
supply piping system at test
pressures equal to or less than
1/2 psig (3.5 kPa).
When connecting unit to propane
gas make certain the propane gas
tank is equipped with its own high
pressure regulator in addition to the
pressure regulator supplied with the
appliance. The maximum gas pres-
sure to the appliance regulator is not
to exceed 14.0" water column from
the propane gas tank.
NATURAL GAS
The cooktop is shipped from the fac-
tory for use with natural gas only.
The gas supply to the appliance regu-
lator must be a minimum of 6.0"
water column.
PROPANE GAS
The cooktop must be converted for
use with propane gas use Kit #
NLPKIT5 P/N 35-00-622 which con-
tains new burner jets (orfices) and
instruction for adjusting valves and
regulator.
CAUTION:
Do not attempt any adjustment of
the pressure regulator, except con-
version to propane.
Turn on gas and check supply line
connections for leaks using a soap
solution. Do not use a flame of
any sort.
CAUTION: