Thermax CP3 Water Dispenser User Manual


 
TROUBLESHOOTING
System Will Not Operate 1) Plugged into dead outlet
2) Blown fuse or breaker
3) Defective power cord
4) Defective switch
5) Loose wiring
6) Improper connection
1) Plug into live grounded outlet
2) Replace fuse or breaker
3) Replace power cord
4) Replace switch
5) Properly connect wiring
6) Press tightly into outlet
CONDITION CAUSE CORRECTION
Vacuum Motor Will Not Run 1) Main power not activated
2) Loose wiring
3) Defective vacuum switch
4) Defective vacuum motor
1) Active main power switch
2) Tighten and connect wiring
3) Replace vacuum switch
4) Replace vacuum motor
Pump Will Not Run 1) Main power not activated
2) Defective pump switch
3) Loose wiring
4) Plugged spray jet
5) Lint buildup in hose coupling
6) Kink in solution hose
7) Defective pump
1) Activate main power
2) Replace pump switch
3) Tighten and connect wiring
4) Remove blockage
5) Disassemble and remove lint
6) Straighten hose
7) Replace pump
Pump Runs But Will Not
Spray/Weak Spray
1) Solution tank empty
2) Obstructed spray jet
3) Obstructed hose coupling
4) Obstructed solution filter
5) Hose damage
6) Pump components
wearing out
1) Refill solution tank
2) Remove blockage
3) Remove obstruction
4) Clean filter
5) Replace necessary hose
6) Replace pump
Loss of Vacuum Suction 1) Recovery dome not seated
2) Obstruction in vac hose
3) Obstruction in wand
4) Screen filter clogged
5) Recovery dome needs gasket
1) Re-seat for better seal
2) Remove obstruction
3) Remove obstruction
4) Remove debris
5) Replace dome gasket
12