GENERAL INSTALLATION DATA
This equipment is designed and sold for commercial use only by personnel trained and experienced
in its operation and is not sold for consumer use in and around the home nor for use directly by the
general public in food service locations. For equipment to be used by the general public, please
contact the factory.
This gas appliance is equipped for the types of gas indicated on the nameplate mounted on the front
panel. It is shipped adjusted for use on natural gas.
The installation of the Appliance should conform to the NATIONAL FUEL GAS CODE "ANSI
Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY RULES AND REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT
CAN/CGA-B149.1 NATURAL GAS INSTALLATION CODE OR CAN/CGA-B149.2
PROPANE INSTALLATION CODE AND LOCAL CODES WHERE APPLICABLE.
WARNING: Improper installation, adjustment, alteration, service or maintenance
can cause property damage, injury or death. Read the installation, operating and
maintenance instructions thoroughly before installing or servicing the equipment.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINITY OF THIS OR ANY OTHER APPLIANCE. KEEP THE APPLIANCE AREA CLEAR
AND FREE FROM COMBUSTIBLES.
This appliance, its pressure regulator and its individual shutoff valve must be disconnected from the
gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2
PSIG. This appliance and its pressure regulator must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure testing of the gas supply piping system
at test pressures equal to or less than 1/2 PSIG. For your protection, we recommend a qualied
installing agency install this appliance. They should be familiar with gas installations and your local
gas requirements. In any case, your gas company should be called to approve the nal installation.
In addition, there should be posted, in a prominent location, detailed instructions to be followed in the
event the operator smells gas. Obtain the instructions from the local gas supplier.
LEVELING UNIT
Units are shipped with feet detached. To attach feet, remove the grates, lay unit on it's side and screw
feet into sockets on bottom. Level unit by adjusting the (4) feet which have an adjustment of 1-3/4" for
accurate and perfect line-up with other Star-Max series units.
DO NOT REMOVE FEET.
GAS PIPING
Gas piping shall be new, clean and of such size and so installed as to provide a supply of gas sufcient
to meet the full gas input of the appliance. If the appliance is to be connected to existing piping, it
shall be checked to determine if it has adequate capacity. Joint compound (pipe dope) shall be used
sparingly and only on the male threads of the pipe joints. Such compounds shall be resistant to the
action of L.P. gases. WARNING: Any loose dirt or metal particles which are allowed to enter the gas
lines on the appliance will damage the automatic valve and affect its operation. When installing this
appliance, all pipe and ttings must be free from all internal loose dirt.