Trane CG-PRC011-EN Refrigerator User Manual


 
5
CG-PRC011-EN
Leading in Efficiency and Reliability with State-Of-The-Art
Scroll Compressor Technology
Efficiency
The energy efficiency of the scroll chiller
results in energy costs lower than any
other comparable chiller. Full load
efficiencies are improved beyond
reciprocating chillers, but part load
efficiencies are simply unmatched by any
other manufacturer.
Superior efficiencies are obtained by
combining many of the traditional scroll
chiller energy efficient features with the
Trane scroll compressor technology.
HERES HOW:
Scroll compressors positive
displacement design
Dual refrigerant circuits (40-60 ton units)
Multiple compressors
Optimum system design
Reduced friction
No valves
Advanced heat transfer surfaces
Chart illustrates low torque variation of the
Trane scroll compressor vs reciprocating
compressor.
Graph illustrates Trane scroll chillers superior annual energy costs vs typical reciprocating
chillers.
Features and
Benefits
Operating Torque
Reliability
The Trane scroll chiller with many new
improvements, now brings an exciting
new compressor to the commercial
market the Trane scroll compressor.
Trane has designed the scroll
compressor to be a leader in reliability.
HERES HOW:
Simple design with 64 percent fewer
parts than equal capacity reciprocating
compressor.
Scroll compliance allows liquid and dirt
to pass through without damaging
compressor (liquid slugging resistant).
Advanced microelectronics protect both
compressor and motor from typical
electrical fault conditions.
Scroll compressors have less than a
third the torque variations of a
reciprocating compressor.
Years of laboratory testing have
optimized compressor and chiller
systems reliability.
Water-cooled scroll chillers are factory
tested.
ASHRAE Standard 90.1
All Trane
chillers meet and exceed the new
efficiency levels mandated by ASHRAE
Standard 90.1. This new standard
requires higher efficiencies than past
technologies can deliver. In fact, energy
efficiency is so paramount the US
Federal Government has adopted
standard 90.1. Federal Executive Order
mandates energy consuming devices
procured must be in the top 25% of their
class. In the case of chillers, ASHRAE
90.1 is the product standard for
measurement.
Risk.
Not only has ASHRAE 90.1 been
adopted by the US Federal Government,
its expected to be adopted domestically,
if not globally, in the future. Make sure
that your chillers as well as your entire
HVAC system complies, or you may be
caught retrofitting your project with new
equipment and paying extra design
dollars if the code changes during
construction.
Tranes CGWE was designed with the
end users requirements in mind.
Efficiency and reliability were primary
design concerns with this latest
generation machine.
Scroll Chiller Energy Usage Savings
Kilowatt Hours
Chiller Load (%)
Typical Reciprocating
Chiller
Scroll Chiller
10-20% Annual Energy Savings