SOMETHING NOT WORKING
Symptom
No power to the appliance
The light does not come on
The temperature in the fridge
The compressor runs continously
Noise
Water under the salad crispers
Solution
Check there is power at the socket.
Check there is not a power cut by checking the
household lights.
Check the fuse has not blown.
Ensure that the bulb is correctly fitted.
Replace the bulb if it has blown.
Check the door light switch is not jammed.
Check the thermostat control knob in the fridge is
turned to the correct setting relative to ambient
conditions.
Check the ambient temperature is within the
applianceÕs operating limits of 10¡C to 32¡C.
Relocate the appliance if necessary.
Adjust the thermostat control knobto give correct
temperature control. See ÒSetting the temperatureÓ.
Check that the door is closed.
Large quantities of food have recently been placed in
the cabinet and/or door is frequently opened.
Check that air ventilation is not obstructed.
Refer to normal operating sounds.
Check the drain hole is not blocked. (see
Maintenance and Cleaning).
If the appliance is not working correctly, please carry out the following checks before contacting your local
Service Force Centre
If, after the above checks, there is still a fault, call your local Service Force Centre.
In-guarantee customers should ensure that the above checks have been made as the engineer will make a
charge if the fault is not a mechanical or electrical breakdown.
Please note that proof of purchase is required for any in-guarantee service calls.
13
TECHNICAL SPECIFICATIONS
DIMENSIONS
Height 124 cm
Width 55 cm
Depth 60 cm
POWER SUPPLY VOLTAGE AND FREQUENCY 220-240 V / 50 Hz
TOTAL POWER ABSORBED 110 W
AVERAGE DAILY UNITS ELECTRICITY * 0.55 kWh
GROSS CAPACITY 235 l
NET CAPACITY 230 l
* This figure is based on standard test results in accordance with European Standard EN 153.