True Manufacturing Company GDIM-49 Refrigerator User Manual


 
............ www.truemfg.com ............
............ www.truemfg.com ............
True Food Service Equipment, Inc.
True Food Service Equipment, Inc.
15
15
15
15
Condensers accumulate dirt and require cleaning every 30 days. Dirty condensers result in
compressor failure, product loss, and lost sales... which are not covered by warranty.
If you keep the Condenser clean you will minimize your service expense and lower your electrical
costs. The Condenser requires scheduled cleaning every thirty days or as needed.
Air is pulled through the Condenser continuously, along with dust, lint, grease, etc.
A dirty Condenser can result in NON-W
ARRANTEED part & Compressor Failures, Product Loss, and
Lost Sales.
Proper cleaning involves removing dust from the Condenser. By using a soft brush, or vacuuming
the Condenser with a shop vac, or using CO2, nitrogen, or pressurized air.
If you cannot remove the dirt adequately, please call your refrigeration service company.
On most of the reach-in units the condenser is accessible in the rear of the unit. You must remove
the cabinet grill to expose the Condenser.
The Condenser looks like a group of vertical fins. You need to be able to see through the condenser
for the unit to function at maximum capacity. Do not place filter material in front of condensing coil.
This material blocks air-flow to the coil similar to having a dirty coil.
THE CLEANING OF THE CONDENSER IS NOT
COVERED BY THE WARRANTY!
HOW TO CLEAN THE CONDENSER:
1. Disconnect the electrical power to the unit.
2. Remove the louvered grill.
3. Vacuum or brush the dirt, lint, or debris from the finned condenser coil.
4. If you have a significant dirt build up you can blow out the condenser with compressed air.
(CAUTION MUST BE USED to avoid eye injury. Eye protection is recommended.)
5. When finished be sure to replace the louvered grill. The grill protects the condenser.
6. Reconnect the electrical power to the unit.
If you have any questions, please call True Manufacturing at 636-240-2400 or 800-325-6152 and
ask for the Service Department. Service Department Availability Monday-Friday 7:30 a.m. to
5:30p.m. and Saturday 7:45 a.m. to 11:45 a.m. CST.
MAINTENANCE, CARE & CLEANING
MAINTENANCE, CARE & CLEANING
Condensing Unit
AirflowAirflowAirflow
Condenser
IMPORTANT WARRANTY INFORMATION