True Food Service Equipment, Inc.
6 6
INSTALLATION / OPERATION INSTRUCTIONS
Step 4
A. Before your new unit is connected to a power
supply, check the incoming voltage with a volt-
meter. If anything less than 100% of the rated
voltage for operation is noted, correct immedi-
ately.
B. Models equipped with 9 ft. (3 m) power cord
must be powered at proper operating voltage at
all times.
Refer to cabinet data plate for voltage.
True requires that a sole use circuit be dedicated
for the unit.
Warning
For proper performance of refrigerated cabinet an
ambient temperature no greater than 75°F (24°C) with
a relative humidity of 55% is required.
WARNING
Compressor warranties are void if compressor burns
out due to low voltage.
WARNING
Power supply cord ground should not be removed!
NOTE
To reference wiring diagram - Remove lower rear
grill. Wiring diagram is positioned on the ballast box
inside lower rear of the cabinet.
ELECTRICAL INSTRUCTIONS