QUICK START GUIDE
4
u-line.com
5. Route water supply line in cable clamp and secure with
screw.
Drain
Models ending in (-00A, -01A) will not be equipped with
factory installed drain pump.
Models ending in (-40A, -41A) will have the factory
installed drain pump.
DRAIN CONNECTION
CAUTION
!
If your U-Line unit did not come with a factory
installed drain pump you must use a gravity
style drain connection. For assistance in
determining if your unit has a pump please
contact U-Line. The floor drain must be large
enough to accommodate drainage from all
attached drains. Follow these guidelines when
installing drain lines to prevent water from
flowing back into the ice maker storage bin and/
or potentially flowing onto the floor, which may
result in personal injury or property damage.
NOTICE
Drain can NOT be located directly below the unit.
Unit has a solid base that will not allow the unit
to drain below itself.
There is a possibility that hose connections may
have loosened during shipment.
Verify all connections and fittings are free from
leaks.
GRAVITY DRAIN
A gravity drain may be used if:
Drain line has at least a 1" drop per 48" (approximately
2 cm drop per 100 cm) of run.
Drain line does not create traps and is vented per local
code.
1. Cut the pre-installed drain tube to length.
2. Connect to your local plumbing per the local code.
3. If necessary, insulate drain line to prevent
condensation.
Normal
Proper Drain
With Trap
Poor Drainage, Water Will Back Up
With Trap and Vent
Proper Drain