U-Line 75WC Beverage Dispenser User Manual


 
12
PROBLEM POSSIBLE CAUSE REMEDY
Unit not cold enough. Control set too Turn control knob
warm CLOCKWISE to set
Check temperatures temperature colder:
(see introduction for Allow 24 hours for
specific temperatures) temperature to stabilize
Light staying on Adjust door so light
switch bracket contacts
switch plunger: See
DOOR ADJUSTMENT
Airflow to front Airflow must not be
grille blocked obstructed to front grille.
See INSTALLATION
Dirty condenser Clean condenser:
coils See CLEANING AND
MAINTENANCE
Door gasket not Adjust door: See
sealing properly DOOR ADJUSTMENT
Unit is too cold. Control set too cold Turn control knob
COUNTER-CLOCKWISE
Check temperatures to set temperature
(see introduction for warmer: Allow 24 hours
specific temperatures) for temperature to
stabilize.
No interior light Loose or burned Tighten or replace
out bulb bulb: See BULB
REPLACEMENT.
Light won’t go out Light on/off switch Turn switch to off.
when door is closed is turned to ON. See LIGHT SWITCH
AND BULB.
Troubleshooting Guide
Never attempt to repair or perform maintenance on the unit
until the main electrical power has been disconnected.
! !
DANGER
41739 Origins WC Body.qxd 10/22/03 1:40 PM Page 12