U-Line CLR2160 Refrigerator User Manual


 
3-63
Section 3 - Service and Repair
10. Once pushed completely into the opening finish routing the drain
tubing to the desired location. Common installations use a floor
drain, standpipe, garbage disposal, or Y-branch tailpiece-type drain
connection
(Figure 73 - 76)
. After the installation is complete,
check the unit to ensure it is level both side to side and front to
back. For disposal connections an optional adapter may be
required (included with the kit) to adapt from the 7/8" connection.
11. For the gravity/floor drain or the standpipe drains it is important to
secure the drain tubing to those items to prevent it from coming
loose. For the disposal or
Y-branch tailpiece connections press the drain tube over the
barbed end on the connector. Make sure the knockout inside the
tailpiece has been removed for both types of connections. Attach
these two with a worm drive hose clamp. Depending on the size of
the
Y-branch or disposer fitting an adapter may be needed to interface
between the 5/8" hose and connection.
12. After all connections have been completed turn the unit to the ON
position. Pour one gallon of water into the ice bin and check all drain
connections for leaks. During this time also ensure that the water
flows from the bin. If the water does not flow from the bin there
may be a problem with the drain connection such as kinks or
improper slope. If your unit has a drain pump an indicator of P1 on
the display will alert to a slow or clogged drain. If any problems are
found, retrace the drain connection, correct the issue and retest
with water.
Figure 73
Figure 74
Figure 75
Figure 76
Waste
Cold
Water
Shut-Off
Valve
Hot
Water
Air Gap
(Optional Hook-Up)
Y-Branch Tailpiece
P60 Pump Required
ULIN_0600a_A
Cold
Water
Hot
Water
Waste
Waste
Shut-Off
Valve
Standpipe
P60 Pump Required
Air gap must
be left between
drain line and
water level.
ULIN_0598a_A
Air Gap
(Optional Hook-Up)
Cold
Water
Hot
Water
Waste
Shut-Off
Valve
Disposal
P60 Pump
Required
ULIN_0599a_A
Waste
Waste
Cold
Water
Shut-Off
Valve
Hot
Water
Floor Drain
Air gap must
be left between
drain line and
water level.
ULIN_0597a_A