CO29FF 11
Ice Cube Thickness Adjustment
Interval - As Required
On ice maker equipped models, the cube size may be
adjusted by changing the amount of water injected into
the ice maker assembly as follows:
Figure 11
1. Remove the ice maker assembly cover (Figure 11).
Figure 12
2. Locate the adjusting screw on the ice maker assembly
control box. The adjusting screw is just below the minus
(-) and plus (+) signs on the control box
(Figure 12)
.
NOTE: Make adjustments in small increments. Too
large of an adjustment could cause the unit to
malfunction.
CAUTION
Too large of an adjustment to the screw can cause
the water to overflow the ice maker and can cause
property damage.
3. Turn the adjusting screw toward the minus (-) sign
(clockwise) for smaller cubes or toward the plus (+) sign
(counterclockwise) for larger cubes.
4. Install the ice maker assembly cover.
IMPORTANTIMPORTANT
Use only genuine U-Line replacement parts. U-Line
ice maker parts are not the same as standard FSP
Whirlpool parts. Using non U-Line parts can reduce
ice rate, cause water to overflow from ice maker
mold, damage the unit, and may void the warranty.
Leveling
It is important that this unit is set level, for proper door
and ice maker operation.
Figure 13
Use a level to check the levelness of the unit from front to
back and from side to side. Level should be placed along
top edge and side edge as shown (Figure 13).
NOTE: This model DOES NOT have leveling feet. This
model MUST be placed on a level surface to operate
properly.