Door Alignment Check and Adjustment
IMPORTANTIMPORTANT
Properly aligned, the door’s gasket should be firmly
in contact with the cabinet all the way around the
door (no gaps). Carefully examine the door’s gasket
to assure that it is firmly in contact with the
cabinet. Also make sure the door gasket is not
pinched on the hinge side of the door.
Figure 14
1. Loosen (do not remove) top (Figure 14) and bottom
hinge screws.
2. Align door squarely with cabinet.
3. Make sure gasket is firmly in contact with cabinet all
the way around the door (no gaps).
4. Tighten bottom hinge screws.
5. Tighten top hinge screws.
Door Reversal
Depending upon the location of the unit, it may be
desirable to change the side on which the door is
mounted. NOTE: On built-in installations, changing the
door mounting to the left side may interfere with ice
bucket removal.
To reverse the door mounting, perform the following:
Figure 15
1. Remove the control knob (Figure 15, 1) by pulling it
away from the cabinet.
2. Remove two grille screws, and remove the grille.
Figure 16
1. Remove top hinge from cabinet (three screws) (Figure
16). Hold door to keep it from falling.
2. Lift the door off the bottom hinge.
Figure 17
3. Remove bottom hinge from cabinet (two screws)
(Figure 17)
.
Figure 18
4. Remove screws on opposite side of cabinet
(Figure 18)
.
Note that there may be a nut behind one or both
screws on either side.
ULIN_0210_A