U-Line pmn Refrigerator User Manual


 
INSTALLATION
SITE PREPARATION
1. Position the unit on a flat, level surface, capable of supporting the
entire weight of the unit. Remember the unit will be significantly
heavier once it is fully loaded.
2. This unit requires grounded and polarized 115 VAC, 60Hz, 15A
circuit (normal household current).
ELECTROCUTION HAZARD!
Electrical Grounding Required. This appliance
is equipped with a three prong (grounding)
polarized plug for your protection against
possible shock hazards.
NEVER remove the round grounding prong from the plug.
NEVER use a two-prong grounding adapter.
NEVER use an extension cord to connect power to the
unit.
Where a two-prong wall receptacle is encountered or a
longer power cord is required, contact a qualified electrician
to have it replaced in accordance with applicable electrical
codes.
NOTE
All U-Line units (except
Stainless Steel models) have
a zero clearance for the door
to open (see Figure 1). See
BUILT-IN INSTALLATION for
additional clearance require-
ments. Stainless steel models
require a minimum of 2-1/2"
door handle clearance when
installed against a wall.
Figure 1
UL124A
DOOR
SWING
CABINET
OR WALL
0"
CLEARANCE
NEEDED
DANGER
! !
5