www.U-LineService.com 4 09/2008
SS1095
MARINE SERIES
Your U-Line product has been designed for either free-
standing or built-in installation. When built-in, your unit
does not require additional air space for top, sides or rear.
However, the front grille must NOT be obstructed and
clearance is required for water and electrical connections
in the rear.
Note: Unit can NOT be installed behind a closed cabinet
door.
Cut-Out Dimensions
IMPORTANT
It is extremely important that the unit sits on a level
surface, as it does not have feet levelers. If it is not level,
the ice mold will not fill evenly.
Model SS1095NF: Follow the cut-out drawing in (Figure
1). The 14-3/8" width allows 1/4" for ease in installation
and removal of the unit. 15-7/8" depth includes the water
line connection.
Note: If you purchase a U-Line WATERHOOKUP kit, the
minimum depth required to install the unit is 15-1/8”. The
recommended receptacle location is an adjacent cabinet.
If receptacle will be behind unit, additional space is
required.
Model SS1095FC: Follow the cut-out drawing in (Figure
2). The unit must sit in a frame structure with a frame
thick enough to accommodate mounting the flange to its
sides and top, and a base high enough to align the door
with other cabinet doors. Make the frame width 14-1/6”
and the height 24-3/4”. This will allow for ease in
installation and removal of the unit for servicing. 16”
depth includes the water line connection.
Note: If you purchase a U-Line WATERHOOKUP kit, the
minimum depth required to install the unit is 15-1/4”. The
recommended receptacle location is an adjacent cabinet.
If receptacle will be behind unit, additional space is
required.
3 Prepare Site
8"
Typical
Counter
Height
34-1/4"
to
35-1/8"
Cut-Out
Height
24-7/8"
to
25"
Filler Panel (Not Provided by U-Line) –
May Be Added Above or Below Unit
to Enclose for a Built-In Look
14-3/8"
15-7/8" Minimum
See Electrical
Specifications
for Power Supply
Figure 1
Cut-Out
Height
24-3/4"
15-3/16"
Minimum Opening
16" Minimum
See Electrical
Specifications
for Power Supply
8" Height
From Floor
Filler Panel (Not Provided by U-Line) –
Needed to Attach Mounting Flange on Unit
Toe Kick
14-1/16"
Cut-Out Width
3/4"
Minimum Flange
Mounting Area
Figure 2