Verona VEFSGG 365 N Range User Manual


 
21
SETTING THE BURNER MINIMUM
When switching from one type of gas to another, the minimum flow rate must also be
correct: the flame should not go out even when passing suddenly from maximum to
minimum flame.
To regulate the flame follow the instructions below:
Semirapid and triple ring burners
Light the burner
Set the gas valve to position
Remove the knob
– With a thin screwdriver turn the screw "F" until adjustment is correct (fig. 2.7).
Inside crown of DUAL burner
Light the DUAL burner
Set the gas valve to
position
Remove the knob
– Using a screwdriver turn the screw "H" until the correct setting is obtained (fig. 2.8).
Outside crowns of DUAL burner
Light the DUAL burner
Set the gas valve to
position
Remove the knob
– Using a screwdriver turn the screw "G" until the correct setting is obtained (fig. 2.8).
For LP/PROPANE gas, tighten the adjustment screws completely.
Fig. 2.8
G
H
regulation
screw
Fig. 2.7