Verona VEGCT424F Appliance Trim Kit User Manual


 
15
b) Any conversion required must be performed by your dealer or a qualified licensed
plumber or gas service company. Please provide the service person with this
manual before work is started on the cooktop. (Gas conversions are the
responsibility of the dealer or end user.)
c) This cooktop can be used with NATURAL or LP/PROPANE gas. It is shipped from
the factory adjusted for use with NATURAL gas.
d) Manifold pressure should be checked with a manometer; NATURAL gas requires
4.0” W.C.P. and LP/PROPANE requires 11.0” W.C.P (see figure 5.4).
Incoming line pressure upstream from the regulator must be 1” W.C.P. higher than
the manifold pressure in order to check the regulator.
The regulator used on this cooktop can withstand a maximum input pressure of
1/2 PSI (14.0” W.C.P). If the line pressure is in excess of that amount, a step-
down regulator will be required.
e) The appliance, its individual shut-off valve, and pressure regulator must be
disconnected from the gas supply piping system during any pressure testing of
that system at pressures in excess of 1/2 PSI (3.5 kPa).
f) The appliance must be isolated from the gas supply piping system by closing its
individual manual shut-off valve during any pressure testing of the gas supply
piping system at test pressure equal to or less than 1/2 PSI (3.5 kPa).
3. Flexible Connections:
If local codes permit, CSA design-certified, flexible metal appliance connector is
recommended for connecting this cooktop to the gas supply line. Do Not kink or
damage the flexible connector when moving the cooktop. The pressure regulator has
3/8" NPT female pipe threads.You will need to determine the fittings required,
depending on the size of your gas supply line, flexible metal connector and shutoff
valve.
To mains
connection
To cooktop
Manifold
test point
pressure
1/8” NPT
Screw
Unscrew
Fig. 5.4