ELECTRICAL CONNECTION
EElleeccttrriiccaall RReeqquuiirreemmeennttss
A 115 volt, 60 Hz, AC only 15 amp fused electrical supply is required. (A
time delay fuse or circuit breaker is recommended.) It is recommended
that a separate circuit, serving only this appliance, be provided.
EELLEECCTTRRIICCAALL GGRROOUUNNDD IISS RREEQQUUIIRREEDD OONN TTHHIISS AAPPPPLLIIAANNCCEE..
DDOO NNOOTT UUNNDDEERR AANNYY CCIIRRCCUUMMSSTTAANNCCEESS RREEMMOOVVEE TTHHEE PPOOWWEERR
SSUUPPPPLLYY CCOORRDD GGRROOUUNNDD PPLLUUGG..
DDOO NNOOTT UUSSEE AANN EEXXTTEENNSSIIOONN CCOORRDD
RReeccoommmmeennddeedd GGrroouunnddiinngg MMeetthhooddss
For your personal safety, this refrigerated beverage center must be
grounded. This appliance is equipped with a 7’ (2.1 m) power supply cord having a 3-prong grounding plug. To minimize
possible shock hazard, the cord must be plugged into a mating 3-prong grounding type wall receptacle grounded in
accordance with the National Electrical Code and local codes and ordinances. If the circuit does not have a grounding type
receptacle, it is the responsibility and obligation of the customer to exchange the existing receptacle in accordance with the
National Electrical Code and applicable local codes and ordinances. The third ground plug SHOULD NOT, under any
circumstances, be cut or removed. All UL listed refrigerated beverage centers are equipped with this type of plug.
Power Supply
with 3-prong
grounding plug
Grounding type wall
receptacle
WARNING
ELECTRICAL SHOCK HAZARD
Failure to follow these instructions could result
in fire or electrical shock.
LEG LEVELER INSTALLATION
RReeaadd BBeeffoorree IInnssttaalllliinngg LLeegg LLeevveelleerrss
WWAARRNNIINNGG::
Do not lay unit on top, side, back, or front. If unit is accidentally laid
in any position other than right side up, then the unit must remain in the right side
up position for at least 24 hours before plugging the unit in.
1. Tip unit backwards so there is one foot of clearance on front of the unit. Have
someone to assist you in tilting the unit to prevent it from falling on you while
installing the leg levelers.
2. Screw front two (2) leg levelers into the weldnuts. Leg levelers should be
screwed in unit snug.
3. Repeat steps 1 & 2 with the exception of tipping the unit forwards to screw in
the back two leg levelers.
4. The leg levelers are now installed.
5. The unit should be level from front to back and side to side. If floor conditions
do not allow the unit to sit level, adjust the leg leveler by turning the required
leg leveler counter-clockwise to increase the height and clockwise to reduce
the height.
LLeegg LLeevveelleerr
((44)) ppeerr uunniitt
WWeellddnnuutt
((EEaacchh bboottttoomm
ccoorrnneerr ooff uunniitt))