E4
7 Preparation of the Oven
Separate mounting plate from oven by removing two
screws. See illustration below. Save these screws for use
in section Mounting Oven to Wall, figure /.
Mounting
Plate
Back of Microwave
figure
figure
4
8 Ventilation System (Preparing
Oven for Installation)
This Built-in Microwave Hood is designed for adaptation
to three types of hood ventilation systems. Select the
type required for your installation.
RECIRCULATING — non-vented, ductless.
Follow installation procedure (A). Recirculating requires
the use of the Charcoal Filter, which has already been
installed in the oven.
HORIZONTAL EXHAUST — outside ventilation.
Follow installation procedure (B).
VERTICAL EXHAUST — outside ventilation.
Follow installation procedure (C).
(A) Recirculating: Non-Vented, Ductless
Operation
•The unit is shipped assembled for recirculating.
•The Exhaust Damper Assembly 7 is NOT REQUIRED
for recirculating operation.
(B) Horizontal Exhaust: Outside
Ventilation
figure
figure
5
1) HORIZONTAL EXHAUST: Remove 2 screws from back
edge and 3 screws from the top center of Fan Cover Bracket.
Save 2 screws to be used later and discard remaining 3.
Remove Fan Cover Bracket by sliding it in the opposite
direction of the arrow on the Fan Cover Bracket.
figure
figure
6
Hood Fan Unit
2) HORIZONTAL EXHAUST: Lift Hood Fan Unit carefully
and slip wires out of cavity.
•CAUTION: Do not pull or stretch hood fan wiring.
figure
figure
7
(A) Rotate 180˚
(B)
3) HORIZONTAL EXHAUST: Rotate the Hood Fan Unit 180˚
so that the fan blade openings are facing the back of the
oven. See Figure 7 (A). Replace Hood Fan Unit into the
oven. Be careful not to pinch the wire and the Hood Fan
Unit. See Figure 7 (B).