Viking DUAR154 Refrigerator User Manual


 
5
AARREEAA RREEQQUUIIRREEMMEENNTTSS
UUnniittss CCeerrttiiffiieedd ffoorr IInnddoooorr UUssee -- ((bbllaacckk oouutteerr ccaabbiinneett))
1. Place unit so the front side will be completely unobstructed to provide proper air flow. The unit may be closed in
on the top and three sides, but the front
MMUUSSTT BBEE
unobstructed for air circulation and proper operation.
Installation should be such that the cabinet can be moved for servicing if necessary.
2. Unit should be in a well ventilated area with temperature above 55
0
F (13
0
C) and below 110
0
F (43
0
C). Best results
are obtained at temperatures between 65
0
F (18
0
C) and 80
0
F (27
0
C) for built-in models and between 65
0
F (18
0
C) and
90
0
F (32
0
C) for freestanding models.
3. Provisions for electricity should be determined before placing unit in proper place.
UUnniittss CCeerrttiiffiieedd ffoorr OOuuttddoooorr UUssee -- ((ssttaaiinnlleessss sstteeeell oouutteerr ccaabbiinneett))
MUST BE INSTALLED IN AN AREA PROTECTED FROM THE ELEMENTS, SUCH AS WIND, RAIN, WATER (SPRAY OR DRIP).
1. Place unit so the front side will be completely unobstructed to provide proper air flow. The unit may be closed in
on the top and three sides, but the front
MMUUSSTT BBEE
unobstructed for air circulation and proper operation.
Installation should be such that the cabinet can be moved for servicing if necessary.
2. Unit should be in a well ventilated area with temperature above 40
0
F (4
0
C) and below 110
0
F (43
0
C).
3. Provisions for electricity should be determined before placing unit in proper place.
NNoottee:: HHiinnggee bbrraacckkeett llooccaattiioonn sshhoowwnn iiss ffoorr rriigghhtt--hhiinnggee sswwiinngg..
Door swing pin
Top hinge
bracket
Logo
Bottom hinge
bracket
Light switch activator
REVERSIBLE DOOR (Glass Door Units Only)
PROFESSIONAL SERIES
You can change the door swing from right to left hinge very easily.
1. Simply unscrew the top hinge door swing pin with an 1/8” allen
drive unit and lift door off of the bottom hinge bracket. Flip the
door, remove the light switch activator and replace the light switch
activator on the other end of the door.
2. Remove the door swing pin from bottom right hinge. Move the
bottom, right hinge bracket to the upper, left side of the cabinet
and fasten it in place with its original mounting screws.
3. Install the hinge door swing pin into the top right hinge bracket
and move the bracket to the lower left side of the cabinet. Fasten
it in place with its original screws.
4. Place the plastic washer over the bottom door swing pin on the
top surface of the bottom, left hinge.
5. Position the door on the bottom, left hinge pin and push the door
under the top, left hinge.
6. Line-up the top left hinge hole with the door bushing hole and
insert swing pin. Screw down the door swing pin with the 1/8”
allen drive unit until its head is flush with the top surface of the
top, left hinge.
7. Reposition the logo. Your installation is now complete.
GENERAL INFORMATION
UUnnppaacckk
1. Remove banding from bottom of carton. Lift carton up and off of the refrigerated beverage center
2. Remove all tape and packaging material from the outside and inside of the cabinet.
3. Keep all carton packaging until your refrigerated beverage center has been thoroughly inspected and found to be in
good condition.