Viking F20529 Cooktop User Manual


 
Electrical Requirements
9
Clearance Dimensions
8
H
O
T
R
E
A
R
F
R
O
N
T
H
O
T
R
E
A
R
F
R
O
N
T
3
6
m
i
n
.
(
9
1
.
4
c
m)
*
1
3
m
a
x
.
(
3
3
.
0
c
m
)
6
m
i
n
.
(
1
5
.
2
c
m
)
*
*
1
8
m
i
n
.
(
4
5
.
7
c
m
)
3
-
1
/
8
(
7
.
9
c
m
)
0
” m
in
.
(
0
.
0
c
m
)
3
6
” m
in
.
(
9
1
.
4
c
m
)
*Note: 36” minimum unless using a hood.
**Note: Only applies to combustible surfaces.
Dimensions shown are for use with
combustible surfaces unless otherwise
stated.
Proximity to Side Cabinet Installation
The cooktop may be installed directly to
existing base cabinets.
The cooktop CANNOT be installed directly
adjacent to sidewalls, tall cabinets, tall
appliances, or other side vertical surfaces
above 36” (91.4 cm) high. There must be a
minimum of 6” (15.2 cm) side clearance from
the cooktop to such combustible surfaces
above the 36” (91.4 cm) counter height.
Within the 6” (15.2 cm) side clearance to
combustible vertical surfaces above
36” (91.4 cm), the maximum wall cabinet depth
must be 13” (33.0 cm) and wall cabinets within
this 6” (15.2 cm) side clearance must be 18”
(45.7 cm) above the 36” (91.4 cm) high
countertop.
Wall cabinet above the cooktop
must be a minimum of 36” (91.4 cm)
above the countertop for a full width
of the cooktop.
Minimum Clearances from Adjacent
Combustible Construction
Above countertop 36” (91.4 cm) minimum
Side 6” (15.2 cm)
Rear 0” (0.0 cm)
Within 6” side clearance. Wall cabinets no
deeper than 13” (33.0 cm)
Must be minimum 18” (45.7 cm) above
countertop
Wall cabinets directly above the product must
be minimum 36” (91.4 cm) above the
countertop
Electrical Requirements
Check your local codes regarding this unit.
This cooktop is supplied with a 3-wire, A.C.
208V/120 volt or 120V/240 volt, 60 HZ
electrical system. A white (neutral) is not
needed for this unit. See next section for
grounding instructions. It should be fused
separately.
Refer to the specifications chart for kilowatt
rating and recommended amperage. House
wiring and fusing must comply with local
codes. If no local codes are applicable, wire
in accordance with the National Electrical
Code, ANSI/NFPA 70-latest edition.
Electrical Connection
When making the wire connections, use
the entire length of the conduit provided
(3 feet). The conduit must not be cut.
Connect the red and black leads from the
unit conduit to the corresponding leads in
the junction box. The bare ground wire in the
conduit is connected to the unit frame. When
connecting to a 3-conductor branch circuit,
connect the bare ground connector lead of
the unit to the branch circuit ground (bare
wire or green in color).
WARNING
ELECTRICAL
GROUNDING
INSTRUCTIONS
This cooktop must be electrically
grounded in accordance with local codes
or, in the absence of codes, with the
National Electrical Code, ANSI/NFPA 70-
latest edition. FOR PERSONAL
SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
CAUTION
Be sure the electric power is
off from the breaker box to the
junction box until the cooktop
is installed and ready to
operate. The junction box should be
connected to a suitable ground.
WARNING
The electrical power to the
unit must be shut off while line
connections are being made.
Failure to do so could result
in serious injury or death.
WARNING
FIRE AND ELECTRICAL
SHOCK HAZARD
DO NOT use an extension
cord with this appliance. Such
use may result in fire, electrical
shock, or other personal injury.